Product Description

D2-DC(YX) is a contactless smart card RFID weigand 26/34 125khz reader which gatherting 125Khz & 13.56Mhz, it’s easy for user to install the reader in harsh outdoor conditions with dust, moisture and full sealing. During use, User can freely pluggable without power and without any drivers.

Product Info

Minorder 1

Product Detail

RFID weigand 26 or 34 125khz reader name:
Weigand 26 or 34 output waterproof 125khz access control rfid credit card reader

Ⅰ Technical Parameters
Item Parameters
Frequency 125Khz & 13.56Mhz
Support cards EM(TK4001/EM4100 etc.) & MF(S50/S70/Ntag203 etc.)
Output format 125Khz(EM): 10 digit Hex+Z+Enter
13.56Mhz(MF): 8 digit Hex+Z+Enter
Interface USB
Power Supply DC 5V
Operating Distance 0mm-100mm(related to the card or the environment)
Service Temperature -25℃ ~ +70℃
Distance of transmission
≤5M
Working humidity <90%
Read time <200ms
Read interval <0.5S
Size 114mm×76mm×16mm
Weight About 190G
Cable length 0.5 M
Material of reader PVC
Cable Specifications Shielded Cable
Protection class IP65
Operating System Win XPWin CEWin 7Win 10LIUNXVistaAndroid
Remark 2PC LED  (Red means standby, Green means reader success)
Buzzer

Ⅱ Instructions for use
Method of installation and use
  1. Connect with computer through USB interface directly. When the buzzer sounded, reader into the self-inspection. And the same time, LED turn into red means standby.
  2. Open the output of computer software,such as Notepada word document or Excel sheets.
  3. The mouse in Notepad or WORD document clicking.
  4. Put tag on the top of reader, the software will output a data of the tag.
Detecting device is connected
Open the Device Manager of computer, If appears Humans Input Device that means Reader has successfully into computer.

Ⅲ Precautions
  1. Do not install the reader on the magnetic objects and metal objects, they will seriously affect the RF signal.
  2. If after reading, the tag is still in the induction zone, the RF reader will not send data and without any hints.
Ⅳ Common problems
  1. Operation without feedback: Please check whether the interface plugged in, whether the tag is a valid or whether another RF tag is within the reading range.
  2. Data error: Please check Whether the mouse is moved, whether the reader is in a critical state and whether the cable length is too long.
Ⅴ Picture





 